Seating Configurations for Civic Center


SEATING CAPACITIES
FLOOR SIZE

Wall to Wall - 90' x 210'
Bleachers Extended - 67' x 150'

Due to ice floor piping, semi-trucks are not allowed on the arena floor at any time.

LOADING AREA

Load-in for the arena is accomplished through a 15' x 15' roll-up door in the southwest corner of the arena. Any equipment requiring a loading height greater than 14' must be advanced in order to adjust the interior curtain clearance. Loading for additional trucks is possible through three (3) 13' 6" H x 10' W doors in a backstage area located 40' south of the main load-in door. However, direct passage to the arena from this location is restricted by a width of 6' 10".

SEATING CAPACITIES

Upper Level
3,488
Club Level
468
Ring Seats
632
Lower Level
5,008
Lower Risers
1,407
Floor

1,236 (south stage)

Disabled Seating
178
In the Round
12,508
South end Stage

11,989 (8,299 front of stage)

3/4 House
6,053
Half House
5,491
Mini Bowl
3,711
1/4 House
3,522
Broadway Configuration
2,460
Hockey
9,596
Basketball
12,100
   

RIGGING INFORMATION

East/west beams on 30' centers run the width of the arena.

One center north/south beam runs the length of the arena.

All rigging steel is 87' above the arena floor.

Each beam can hold a maximum weight of 20,000 pounds, with a per point maximum of 5,000 pounds.

Obstructions:

  • One 30' x 25' center scoreboard.
  • One 60' W x 40' L theatrical counterweight grid system located directly north of the scoreboard.
ELECTRICAL INFORMATION

Show Power - Southwest arena wall
1- 600 amp, 208 volt, 5 wire service
1- 200 amp, 208 volt, 5 wire service
1- 400 amp, 208 volt, 5 wire service
1- 200 amp, 208 volt, 5 wire service

The 600 amp and one 200 amp disconnect are powered from a separate substation than the 400 amp and remaining 200 amp services.


Shore Power - Southwest wall of loading area
2 - 30 amp, 208 volt, single phase
1 - 50 amp, 208 volt, single phase
South secure-parking area
2 - 50 amp, 208 volt, single phase

Additional Power - Access hall at northwest end of arena
1 - 200 amp, 208 volt, 5 wire service

DRESSING ROOMS

4 - Team Rooms - 16' x 22' - Common bathrooms and shower areas for each pair of team rooms.

2 - Dressing Rooms - 9' x 11' - Private restroom, shower, and well-lit mirrored area in each room.

1 - Dressing Room - 6' x 14' - Private restroom, shower and well-lit mirrored area.

1 - Green Room - 10' x 14' - Carpeted room with furniture.

1 - Production/Press Office - 10' x 15' Two restricted access phone lines and a restricted access dedicated fax line.

Other meeting rooms and team rooms may be available for rental as needed for additional office or reception space.

Copyright 2014, Donald L. Tucker Civic Center at Florida State University, All Rights Reserved.